What is BEP in a Centrifugal Pump? BEP, or Best Efficiency Point, is the point on a pump’s performance curve where the pump converts the highest proportion of shaft input power into hydraulic output under the specified test conditions. It is a reference point for evaluating operating efficiency, not a mandatory single operating requirement for every application.
This guide explains pump curves, BEP, system curves, operating points, efficiency, NPSH, and pump selection in practical engineering terms, helping plant and maintenance teams evaluate pump performance and operate industrial pumping systems more efficiently.
SECTION 01
What Is a Pump Performance Curve?
A Pump Performance Curve is a graphical representation, published by the manufacturer, of how a specific pump behaves across a range of flow rates at a fixed speed and impeller diameter. It is generated from factory testing under controlled conditions, typically using water at a defined temperature and density, and it forms the basis for every pump selection decision.
A single pump curve sheet typically combines several related curves plotted against flow on the horizontal axis:
- Flow (Q): The volume of fluid moved per unit time, typically in m³/hr, L/s, or GPM.
- Head (H): The energy imparted to the fluid, expressed as the height of a fluid column the pump could theoretically lift, usually in meters or feet.
- Efficiency (%): The ratio of hydraulic output power to shaft input power, plotted as a curve that typically rises, peaks, then falls as flow increases.
- Power (P): The shaft power the driver must supply at each point along the flow range.
- NPSHR: The Net Positive Suction Head Required by the pump at each flow rate to avoid cavitation, plotted as a rising curve.
All of this data is specific to a given pump speed, impeller diameter, and fluid assumption — typically clear water at ambient temperature. Changing the fluid, speed, or impeller trim shifts the curve, which is why curve data should always be verified against actual application conditions rather than assumed to transfer directly from one duty to another.
|
⚙️
Pump Process
|
→ |
📈
Pump Curve
|
→ |
🛠️
System Curve
|
→ |
⚖️
Intersection Point
|
→ |
🎯
Operating Point
|
SECTION 02
How to Read a Centrifugal Pump Curve
Reading a Pump Curve correctly is a Sequential Process. Skipping steps — particularly checking only flow and head — is the most common reason pumps are selected incorrectly.
Identify Required Flow
Establish the design flow in consistent units (m³/hr, L/s, or GPM), along with the normal operating flow and the maximum expected flow. Many systems operate below their design flow for extended periods, so the curve should be checked across that realistic range, not just at the single design point.
Determine Required Head
Total Dynamic Head (TDH) combines static head (the elevation difference the fluid must be lifted), friction losses through pipe, valves, and fittings, and any pressure requirement at the discharge point. Underestimating any one component leads to a pump that cannot meet actual system demand.
Locate the Pump Head-Flow Curve
With required flow and head established, locate where that duty point falls relative to the pump’s head-flow curve. A pump curve slopes downward as flow increases — less head at higher flow, more head at lower flow, within its operating range.
Check Pump Efficiency
Read the efficiency curve at the expected operating flow. Efficiency typically rises from low flow, peaks near BEP, and falls again toward the high-flow end. The efficiency value at the actual operating point — not at BEP — is what determines actual energy consumption.
Check Power Requirement
Confirm the shaft power required at the operating point, then verify the motor rating provides adequate service margin above that figure. Operating power should be checked across the full expected flow range, since shaft power for most centrifugal pumps increases with flow.
Check NPSHR
Compare the pump’s NPSH Required (NPSHR) at the operating flow against the NPSH Available (NPSHA) from the actual suction arrangement. The margin between NPSHA and NPSHR — not just their individual values — determines cavitation risk, and that margin typically narrows as flow increases.
Engineering Tip — Pump Curve Reading Checklist
- Design, normal, and maximum flow confirmed
- Total Dynamic Head calculated, including static, friction, and pressure components
- Operating point located on the head-flow curve
- Efficiency read at the actual operating point, not assumed from BEP
- Shaft power verified against motor rating with adequate margin
- NPSH margin (NPSHA minus NPSHR) confirmed across the operating range
SECTION 03
What Is the Best Efficiency Point (BEP)?
BEP is the flow rate at which a given pump converts the highest proportion of shaft power into usable hydraulic energy, under its rated speed, impeller diameter, and test fluid conditions. On the curve sheet, it appears as the peak of the efficiency curve, and it typically does not correspond to the highest flow the pump can produce — it is a hydraulic optimum, not a maximum-capacity point.
BEP is specific to each pump design. Two pumps rated for the same flow and head can have BEP located at different points on their respective curves, because impeller geometry, casing design, and internal clearances all influence where hydraulic losses are minimized. BEP also shifts if the pump’s speed or impeller diameter is changed from the tested configuration.
It is important not to treat BEP as a mandatory single operating requirement. Manufacturers typically define a preferred operating region around BEP — a range within which the pump operates reliably and efficiently — rather than expecting every application to hit BEP exactly. The distinction matters: BEP → Preferred Operating Region → Actual Operating Point represents three related but different things, and engineers should evaluate the actual operating point against the manufacturer’s recommended range, not against BEP alone.
SECTION 04
Why Is Operating Near BEP Important?
Operating within a pump’s preferred region generally supports balanced hydraulic conditions inside the pump: even flow distribution around the impeller, moderate radial and axial loading, and stable internal flow patterns. Moving away from that region — in either direction — changes those internal flow patterns and can increase mechanical stress on the shaft, bearings, and seals, though the degree of impact depends significantly on the specific pump’s design and construction.
| Operating Region | Typical Condition | Possible Effects | Engineering Concern |
|---|---|---|---|
| Near BEP | Efficient operating region | Balanced hydraulic operation | Preferred region where applicable |
| Low-Flow Region | Below normal operating range | Recirculation, heat rise, vibration | Reliability and stability |
| High-Flow Region | Above normal operating range | Higher power and NPSH demand | Hydraulic and mechanical loading |
| Far From Preferred Region | Off-design operation | Increased stresses and losses | Reliability and maintenance |
These effects are not universal across every pump type and application. A multistage pump, an end suction ANSI pump, and a vertical turbine pump respond differently to off-BEP operation, and some processes require sustained operation away from BEP by design. The table above describes general tendencies, not fixed outcomes — always cross-check against the specific manufacturer’s curve and recommended operating range.
SECTION 05
Understanding the Pump Operating Point
How is the pump operating point determined? The operating point is the flow and head at which the pump curve intersects the system curve. It is not selected directly by the engineer — it is the natural result of the pump’s hydraulic capability meeting the system’s actual resistance.
Because the operating point emerges from an intersection rather than a single chosen value, it will shift whenever either curve changes — a throttled valve, a fouled strainer, or a change in tank level all move the system curve and, with it, the actual flow and head the pump delivers.
Consider a simple example: a pump curve shows 60 m of head at 100 m³/hr, dropping to 50 m at 130 m³/hr. If the system curve calculated for the piping and process requires 55 m of head at 115 m³/hr, the intersection of the two curves — not the pump’s rated point alone — determines that the pump will actually operate somewhere close to that combination, not necessarily at the flow and head printed on the pump’s nameplate.
This is why selecting a pump using only Required Flow + Required Head is not sufficient. The engineer should also evaluate the resulting operating point against BEP and the preferred operating region, efficiency at that point, NPSHR versus NPSHA, shaft power against motor rating, and the pump’s overall operating range across expected process variation.
SECTION 06
What Is a System Curve?
What is a system curve? A system curve is a plot of the total head required to move fluid through a specific piping and process configuration at various flow rates. Unlike the pump curve, it is determined entirely by the piping system, not by any pump.
A system curve is built from two categories of resistance: static head, which does not change with flow — elevation difference and any fixed pressure requirement — and flow-dependent losses, which increase with the square of flow and come from pipe friction, valves, fittings, filters, and other process resistance. This relationship is commonly expressed as:
System Head = Static Head + Flow-Dependent Losses + Other Required Head
Because flow-dependent losses rise sharply with flow, system resistance generally increases as flow increases, which is why a system curve slopes upward — the opposite direction to a typical pump head-flow curve, which slopes downward. It is precisely this opposite slope that produces a single, predictable intersection point when the two curves are plotted together.
SECTION 07
Pump Curve vs System Curve
| Parameter | Pump Curve | System Curve |
|---|---|---|
| Represents | Pump hydraulic capability | System resistance |
| Main Relationship | Flow vs. head generated | Flow vs. head required |
| Determined By | Pump design, speed, impeller diameter | Piping and process conditions |
| Changes With | Speed, impeller diameter, pump configuration | Valve position, piping, fouling, process conditions |
| Role in Intersection | Determines operating point | Determines operating point |
The intersection of the pump curve and the system curve determines the actual operating point — not the pump alone, and not the system alone. Any pump selection process that evaluates the pump curve in isolation, without plotting it against a realistic system curve, is working with incomplete information.
SECTION 08
Pump Efficiency Curve Explained
Why does pump efficiency change with flow? Efficiency changes with flow because hydraulic losses inside the pump — friction, turbulence, and internal leakage — vary at different flow rates. These losses are minimized near BEP and increase as flow moves away from that point in either direction.
Overall pump efficiency reflects three loss categories: hydraulic losses from friction and turbulence as fluid moves through the casing and impeller passages, mechanical losses from bearing and seal friction, and volumetric losses from internal recirculation past wear rings and clearances. Combined, these losses determine how much of the shaft power actually converts to useful hydraulic output.
Pump Efficiency = Hydraulic Power ÷ Shaft Power
Hydraulic power is the useful output delivered to the fluid, and for SI units it is expressed as:
Ph = ρgQH
Where Ph is hydraulic power in watts, ρ is fluid density in kg/m³, g is gravitational acceleration (9.81 m/s²), Q is flow rate in m³/s, and H is head in meters. Actual shaft power is always greater than hydraulic power, because the pump’s internal losses mean the driver must supply more energy than is ultimately delivered to the fluid — this difference is what the efficiency curve quantifies at every point along the flow range.
SECTION 09
Factors That Shift the Pump Operating Point
Because the operating point results from an intersection of two curves, anything that changes either curve moves the operating point — often without any deliberate adjustment to the pump itself.
| Change | Effect on System/Pump Curve | Operating Point Impact |
|---|---|---|
| Valve throttling | Increases system resistance | Flow decreases, head increases |
| Pipe fouling / scaling | Increases friction losses over time | Gradual flow reduction |
| Strainer / filter blockage | Adds resistance, reduces NPSHA | Flow drops, cavitation risk rises |
| Fluid viscosity increase | Raises friction losses and pump losses | Flow decreases, power demand rises |
| Fluid density change | Alters shaft power requirement | Power changes; head largely unaffected |
| Tank level change | Shifts static head component | Operating point moves along pump curve |
| Pump speed change | Shifts the entire pump curve | New intersection at different flow/head |
| Impeller diameter change | Shifts head-flow curve | Operating point relocates on new curve |
| Parallel pump operation | Combines flow at each head value | Higher combined flow, shared duty |
| Series pump operation | Combines head at each flow value | Higher combined head at same flow |
| Process demand change | Alters required flow or pressure | System curve shifts up or down |
SECTION 10
How Pump Speed Affects Performance
For a given pump running at similar operating conditions, the centrifugal pump affinity laws describe approximately how flow, head, and power change with speed:
- Flow: Q2/Q1 ≈ N2/N1 — flow varies approximately in direct proportion to speed.
- Head: H2/H1 ≈ (N2/N1)² — head varies approximately with the square of the speed ratio.
- Power: P2/P1 ≈ (N2/N1)³ — power varies approximately with the cube of the speed ratio.
This relationship is the technical basis for Variable Frequency Drives (VFDs) as an energy-efficient alternative to valve throttling: because power scales with the cube of speed, modest speed reductions can meaningfully reduce power draw when a system’s flow requirement genuinely varies over time, rather than dissipating excess pump energy across a throttled valve.
Warning — Affinity Law Limitations: These relationships are approximations that hold reasonably well for moderate speed changes on a given pump, assuming similar flow conditions and negligible changes in efficiency. They do not account precisely for changes in NPSHR, system static head, or pump-specific hydraulic behavior at very different speeds. Affinity law estimates should be verified against actual manufacturer data before being used for final speed or VFD sizing decisions.
SECTION 11
How Impeller Diameter Affects Pump Performance
Impeller trimming — machining down the impeller’s outer diameter — is a common method for adjusting a pump’s head-flow curve to better match a specific system curve without changing the casing or motor. A smaller diameter generally reduces the head the pump develops at a given flow and reduces the shaft power required, effectively producing a new, lower curve within the family of curves available for that pump model.
Impeller trimming is not a linear or universally predictable adjustment across every pump design, and the relationship between trim percentage and resulting head or flow reduction varies by impeller and casing geometry. Trimming decisions should be based on the manufacturer’s actual trim curves for that specific pump model, rather than generic percentage-based approximations, since assumptions that hold for one impeller geometry may not transfer accurately to another.
SECTION 12
Common Pump Operating Problems
| Problem | Possible Cause | Effect | Recommended Engineering Action |
|---|---|---|---|
| Operating too far left of BEP | Oversized pump, excessive throttling | Recirculation, vibration, heat rise | Review sizing; consider VFD or impeller trim |
| Operating too far right of BEP | Undersized pump, low system resistance | Higher power draw, reduced NPSH margin | Verify system curve; reassess pump sizing |
| Excessive throttling | Valve used as primary flow control | Wasted energy, artificial system curve steepening | Evaluate VFD control or impeller trim instead |
| Incorrect impeller diameter | Wrong trim selected at specification stage | Operating point mismatched to system | Re-verify against manufacturer trim curves |
| Increased system resistance | Fouling, scaling, strainer blockage | Reduced flow, operating point drifts left | Inspect and clean piping, strainers, filters |
| Insufficient NPSH margin | High flow operation, poor suction design | Cavitation, impeller damage, noise | Review suction piping and NPSHA calculation |
| Parallel pump mismatch | Dissimilar pump curves running together | Uneven load sharing, one pump backed off curve | Match pump curves or review control strategy |
| Incorrect pump selection | Selection based on flow and head alone | Chronic inefficiency or reliability issues | Reselect using full curve evaluation |
SECTION 13
How to Improve Pump Energy Efficiency
How can pump energy consumption be reduced? By selecting a correctly sized pump, operating within its recommended range, minimizing unnecessary throttling, controlling flow with speed variation where appropriate, and keeping the system’s resistance — piping, strainers, and valves — well maintained.
- Select the correct pump size for actual, not overstated, design conditions
- Operate within the manufacturer’s recommended flow range
- Avoid unnecessary throttling as a routine flow control method
- Evaluate VFD control where flow demand genuinely varies
- Reduce excessive system resistance through optimized pipe sizing
- Maintain clean strainers and filters to avoid added resistance
- Maintain correct impeller condition, free of wear and buildup
- Monitor the operating point periodically against the original curve
- Monitor motor loading to catch drift from expected power draw
- Maintain alignment, bearings, and seals to avoid added mechanical losses
- Review parallel pump operation for balanced load sharing
- Eliminate unnecessary bypass or recirculation flow
Best Practice: Pump energy optimization is a system-level exercise, not only a pump-level exercise. A perfectly selected pump running against an unnecessarily restrictive system curve, or an oversized pump throttled back with a valve, will still waste energy regardless of how efficient the pump itself is at its own BEP.
SECTION 14
Pump Selection Using the Performance Curve
A structured, curve-based selection process reduces the risk of chronic inefficiency or reliability problems after installation.
SECTION 15
Example — How to Read a Pump Curve
Consider an illustrative duty point of 120 m³/hr at 55 m of head. An engineer evaluating a candidate pump for this duty would work through the following steps:
-
-
- Plot the duty point (120 m³/hr, 55 m) on the candidate pump’s head-flow curve.
- Review where the pump’s actual curve passes relative to that point — the true operating point is where the pump curve meets the system curve, which may sit slightly off the nameplate duty point.
- Determine the resulting operating point in terms of actual flow and head delivered.
- Check how close that operating point falls to the pump’s BEP and preferred operating region.
- Read the efficiency curve at that operating point to establish actual expected efficiency.
- Read the power curve at that point and compare it against the proposed motor’s rated power, allowing for service margin.
- Read NPSHR at that flow and compare it against the calculated NPSHA for the actual suction arrangement.
- Confirm the motor is suitable across the full expected operating range, not just the design point.
- Evaluate the operating margin available if process conditions vary from the base design case.
-
Worked Result — Curve Intersection
Plotting the nameplate duty against the candidate pump’s actual curve, the pump runs slightly under 55 m at 120 m³/hr — a normal effect of curve tolerance. The true operating point is where the pump curve crosses the system curve, not the nameplate figure itself.
| Parameter | Value |
|---|---|
| Nameplate duty | 120.0 m³/hr @ 55.0 m |
| Pump curve head at 120 m³/hr | 54.3 m (−1.3%) |
| System curve head at duty flow | 55.0 m |
| True operating point (curve intersection) | 118.6 m³/hr @ 54.4 m |
| Deviation from nameplate duty | −1.2% flow, −1.1% head — within ±3% curve tolerance |
Worked Result — BEP Proximity
The candidate pump’s BEP is at 122 m³/hr, and its preferred operating region is 80–110% of BEP flow. The operating point of 118.6 m³/hr falls at 97.2% of BEP flow — comfortably inside the preferred band.
Operating point as % of BEP flow (scale 0–130%)
97.2% of BEP flow — inside the 80–110% preferred band
Worked Result — Efficiency, Power & NPSH at the Operating Point
| Check | At Operating Point (118.6 m³/hr) | Reference / Limit | Result |
|---|---|---|---|
| Efficiency | 78.2% | 78.5% peak (at BEP) | 0.3 pts off peak |
| Shaft power | 22.5 kW | 30 kW motor rating | +33% margin |
| NPSH margin | NPSHA 11.23 m vs. NPSHR 5.15 m | 1.5 m / 1.3× guideline | 6.08 m margin (2.18×) |
Worked Result — Motor Suitability Across the Expected Range
Checking one point isn’t enough — shaft power keeps climbing past BEP, so the motor has to be checked across the full range the process can actually produce.
| Flow (m³/hr) | Head (m) | Efficiency | Shaft Power (kW) | Motor Loading |
|---|---|---|---|---|
| 100 | 56.3 | 77.0% | 19.9 | 66% |
| 118.6 (operating point) | 54.4 | 78.2% | 22.5 | 75% |
| 140 | 52.5 | 77.0% | 26.0 | 87% |
| 163 (overload threshold) | 49.3 | 75.2% | 30.0 | 100% |
| 180 (curve end / runout) | 47.0 | 69.0% | 33.4 | 111% — overload |
Margin if process conditions vary: a lower static head, a fouled strainer, or an open bypass shifts the system curve toward higher flow. In this example, the bounding high-flow case (180 m³/hr) pushes shaft power to 33.4 kW against a 30 kW motor — a genuine overload. That’s managed by restricting runout with a throttle valve, an orifice, or an impeller trim, rather than relying on the motor’s own service factor to absorb it.
Important: The 120 m³/hr at 55 m example values above are illustrative only and are not SAM Turbo product specifications. Actual pump curve evaluation must always use the specific manufacturer’s tested curve data for the pump model under consideration.
SECTION 16
Common Pump Curve Selection Mistakes
|
💡Engineering Tip A good pump selection balances the actual operating point, efficiency, |
|---|
SECTION 17
Pump Performance Monitoring After Installation
Once a pump is commissioned, ongoing monitoring is what confirms it continues to operate where it was intended to. Key parameters worth tracking include flow, suction pressure, discharge pressure, differential head, motor power and current, pump speed, vibration, bearing temperature, mechanical seal condition, and the calculated operating point itself.
Trend monitoring over time — rather than single-point readings — is what reveals meaningful change. A gradual drop in flow at constant speed often points to system changes such as fouling or a partially closed valve. A gradual increase in vibration or bearing temperature often points to pump degradation. Comparing current readings against commissioning baselines is one of the most effective ways to catch performance deterioration before it causes an unplanned failure.
SECTION 18
Preventive Maintenance for Efficient Pump Operation
Maintaining the mechanical condition of a pump directly supports maintaining its hydraulic performance. Worn impellers, degraded wear rings, and misalignment all shift a pump’s effective curve away from its original tested performance, even if nothing else in the system has changed.
Pump Maintenance Frequency GuideRecommended checks to monitor pump performance and operating condition
Maintenance frequency should be adapted to the pump design, service conditions, |
|---|
Actual maintenance frequency should follow the pump manufacturer’s recommendations, the severity of the operating conditions, the criticality of the equipment to the process, and the plant’s own maintenance procedures — the table above is a general reference point, not a fixed rule for every installation.
SECTION 19
How SAM Turbo Supports Efficient Industrial Pumping
Selecting a pump that performs efficiently over its actual operating life requires evaluating flow, head, the resulting operating point, BEP proximity, efficiency, NPSH margin, materials, and application requirements together — not any single figure in isolation.
SAM Turbo Industry Pvt. Ltd. has been engineering pumps for demanding industrial applications for more than 55 years. SAM Turbo’s engineering team works with plant engineers, EPC contractors, and procurement teams to review actual process conditions and system requirements before recommending a pump, with the goal of a selection that performs reliably within its intended operating range rather than one chosen from flow and head figures alone.
This application-focused approach considers the full picture relevant to performance and reliability: flow, head, operating conditions, pump efficiency, BEP and preferred operating region, NPSH, materials, and the specific requirements of the application — supporting pump selections built on engineering evaluation rather than nameplate matching alone.
SECTION 20
Conclusion
A pump curve describes what a pump can do; a system curve describes what the application demands; their intersection — the operating point — describes what actually happens once the pump is running. BEP marks the pump’s most efficient flow rate under tested conditions, and while operating near the preferred region generally supports efficient, stable operation, the appropriate range for any specific pump depends on its design, the manufacturer’s recommendations, and the actual application conditions.
Correct pump selection means evaluating the full curve — flow, head, efficiency, power, and NPSHR — against a realistic system curve, not matching flow and head figures in isolation. Ongoing performance monitoring after installation is what confirms a pump continues to operate where it was intended to, and preventive maintenance protects the mechanical condition that keeps its actual performance close to its original tested curve. Ultimately, energy efficiency in pumping is a complete system consideration, encompassing the pump, the piping, the control strategy, and the process demand together.
Contact Us
If you need help selecting a pump for a specific duty, evaluating an existing pump’s operating point, or reviewing energy-efficiency opportunities across a pumping system, SAM Turbo’s engineering team is available to review your process conditions and recommend a suitable pump selection. Contact SAM Turbo’s engineering team to discuss your requirement.
Frequently Asked Questions
What is a pump performance curve?
A pump performance curve is a manufacturer-published graph showing how a specific pump’s head, efficiency, power, and NPSHR vary across a range of flow rates at a fixed speed and impeller diameter, based on factory test data.
What is BEP in a centrifugal pump?
BEP, or Best Efficiency Point, is the flow rate at which a pump achieves its highest efficiency — converting the greatest proportion of shaft power into hydraulic output — under its rated speed and test conditions.
Why is BEP important for pump efficiency?
BEP identifies the flow region where a pump generally operates with balanced hydraulic conditions and the lowest internal losses. Operating near this region typically supports lower energy consumption and reduced mechanical stress, though the practical impact depends on the specific pump design.
How do I read a centrifugal pump curve?
Identify the required flow and Total Dynamic Head, locate that point on the pump’s head-flow curve, then read the corresponding efficiency, shaft power, and NPSHR values at that same flow to confirm the pump suits the application.
What is the pump operating point?
The operating point is the flow and head at which the pump’s own performance curve intersects the system curve of the connected piping and process. It reflects what the pump actually delivers, not just its rated capability.
What is the difference between a pump curve and a system curve?
A pump curve represents what the pump can hydraulically deliver, determined by its design, speed, and impeller diameter. A system curve represents what the piping and process require, determined by static head and flow-dependent losses. Their intersection sets the actual operating point.
Does a pump need to operate exactly at BEP?
No. BEP is a reference point for efficiency, not a mandatory operating requirement. Manufacturers typically define a preferred operating region around BEP, and many applications operate reliably within that broader range rather than at the exact BEP flow.
How does pump speed affect flow, head, and power?
Per the affinity laws, flow varies approximately in direct proportion to speed, head varies approximately with the square of the speed ratio, and power varies approximately with the cube of the speed ratio, for similar operating conditions on a given pump.
How can pump energy efficiency be improved?
By selecting a correctly sized pump, operating within its recommended range, minimizing unnecessary throttling, considering speed control where flow demand varies, and maintaining low system resistance through clean strainers, well-sized piping, and good mechanical condition.
What happens when a pump operates far from BEP?
Operating well away from the preferred region can increase radial and axial loading, contribute to internal recirculation, vibration, and heat rise, and reduce NPSH margin at high flow. The severity varies significantly by pump design, so actual risk should be assessed against the specific manufacturer’s curve.
Need Expert Guidance on Pump Selection and Efficiency?
Consult SAM Turbo’s engineering team for selecting and evaluating industrial pumps based on flow, head, operating point, BEP, NPSH, efficiency, and application requirements.